CBVYL - SOLUTION '5', EU-TEST-IT BASE METAL (SUPP DATA)
- MSDS: CBVYL
- Manufacturer: EUTECTIC CORP
- Product Name: SOLUTION '5', EU-TEST-IT BASE METAL (SUPP DATA)
- National Stock Number: 6630-00N064767
Product Identification
Product ID:SOLUTION '5', EU-TEST-IT BASE METAL (SUPP DATA)
MSDS Date:05/04/1994
FSC:6630
NIIN:00N064767
Kit Part:Y
MSDS Number: CBVYL
Responsible Party
FLUSHING, NY 11358
US
Emergency Phone: 800-221-1433
Info Phone: 800-221-1433
Cage: 72271
Contractor
Telephone: 704-527-9800/ 800-221-1433
Cage: 72271
Ingredients
SODIUM THIOSULFATE, PENTAHYDRATE; (SODIUM THIOSULFATE
CAS: 10102-17-7
RTECS: WE6660000
Fraction By Weight: 10%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHALATION:IRRITATION OF UPPER
RESPIRATORY TRACT. SKIN: PROLONGED CONTACT MAY CAUSE IRRITATION.
EYES: IRRITATION. INGESTION: GASTROINTESTINAL IRRITATION. CHRONIC:
NONE SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH THOROUGHLY W/WATER FOR AT LEAST 15 MINUTES. SKIN:
WASH W/SOAP & WATER. INHAL: REMOVE TO FRESH AIR. INGEST: GET
MEDICAL ASSISTANCE. IF CONSCIOUS, IMMEDIATELY GIVE LARGE AMOUNTS OF
WATER & I NDUCE VOMITING. IF UNCONSCIOUS, INHALATION OF AMYL
NITRITE VAPOR FOR 5 SECONDS AT 15 SECOND INTERVALS. GET MEDICAL
ASSISTANCE FOR ALL CASES OF OVEREXPOSURE. NEVER GIVE ANYTHING BY
MOUTH TO UNCON PERS.
Fire Fighting
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING MATERIALS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE IDENTIFIED. TOXIC GASES PRODUCED:
SULFUR DIOXIDE.
Accidental Release
Spill Release Procedures:SCOOP UP AND DISPOSE OF PROPERLY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. STORE
IN A COOL, DRY PLACE AWAY FROM ACIDS. DO NOT BREATHE DUST OR VAPOR.
Other Precautions:DO NOT GET IN EYES, ON SKIN OR ON CLOTHING. DO NOT
TAKE INTERNALLY.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:PROVIDE ADEQUATE GENERAL MECHANICAL AND LOCAL EXHAUST
VENTILATION TO MEET TLV REQUIREMENTS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:IDENTIFICATION KIT.
Chemical Properties
Spec Gravity:1.69 (H*2O=1)
Solubility in Water:APPRECIABLE (>10%)
Appearance and Odor:ODORLESS AND COLORLESS CRYSTALS DISSOLVED IN WATER
Stability
Stability Indicator/Materials to Avoid:YES
REACTS WITH STRONG ACIDS. ALSO, AVOID OXIDIZERS, IODINE, MERCURY,
SODIUM AND POTASSIUM.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT.
Hazardous Decomposition Products:OXIDES OF SULFUR.
Disposal
Waste Disposal Methods:TO BE PERFORMED IN COMPLIANCE WITH ALL CURRENT
LOCAL, STATE, AND FEDERAL REGULATIONS. CONTACT PROFESSIONAL
DISPOSAL SERVICE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.